Test Procedures; Testing The Motor - Invacare TDX-SP Service Manual

Invacare tdx-sp wheelchair service manual
Hide thumbs Also See for TDX-SP:
Table of Contents

Advertisement

SERVICE MANUAL
7

Test procedures

7.1

Testing the motor

Requirements:
● Phillips screwdriver size 2
● digital multimeter with resistance measurement
Remove the rear panel as described in Chapter 8.1.2.
Pull the motor plug (3) out of the electronic module.
Connect the digital multimeter to the motor plug contacts (3) and measure the resistance
between the contacts.
Note
A resistance of between 0.5 and 5 ohms indicates a motor ready for operation.
A resistance of between 15 ohms and infinity indicates a defective motor. High resistances are
normally caused by bad connections or worn carbon brushes.