Connections and Cabling
Once your switch is properly installed, you should connect all
network and management cables required for your network
applications. Connections may include:
• RJ-45 straight-through cable to the console port
• Ethernet cable to the Ethernet Management Port
(EMP) on the CMM
• Cables to NIs or transceivers
Serial Connection to the Console Port
The console port, located on the CMM module, provides a
serial connection to the switch and is required when logging
into the switch for the first time. By default, this RJ-45
connector provides a DCE console connection.
Serial Connection Default Settings
baud rate
parity
data bits (word size)
stop bits
For information on modifying these settings, refer to the
OmniSwitch AOS Release 7 Switch Management Guide.
October 2010
9600
none
8
1
Ethernet Management Port (EMP)
Cable Requirements
There are specific cable type requirements (i.e., straight-
through or crossover) based on the location of the Ethernet
Management Port (EMP) and the type of device to which it is
connecting. Refer to the information below:
EMP to a Switch
EMP to a Computer or
Workstation
For information on manually configuring Ethernet ports for
cabling requirements, refer to the OmniSwitch AOS Release 7
Network Configuration Guide.
For detailed information on all port types, including console,
EMP, Gigabit Ethernet, and 10 Gigabit Ethernet, refer to the
OmniSwitch 10K Hardware Users Guide.
Straight-through
Crossover
Connections and Cabling
11