2. INSTALLATION

2.1 INSTALLATION REQUIREMENTS

2.1.1 ENVIRONMENT

1.
Temperature Rage: 10°C to 32°C (50°F to 89.6°F)
2.
Humidity Range: 15% to 80% RH
3.
Ambient Illumination: Less than 2,000 lux (do not expose to direct sunlight)
4.
Ventilation: 3 times/hr/person
5.
Do not put the machine in areas with sudden temperature changes. This includes:
Areas directly exposed to cool air from air conditioning
Areas directly exposed to heat from a heating system.
6.
Do not put the machine in areas exposed to corrosive gas.
7.
Do not install the machine at locations over 2,000 m (6,562 ft.) above sea level.
8.
Put the machine on a strong, level base. (Tilting towards any side must be no more than 3
mm.)
9.
Do not put the machine in areas with strong vibrations.

2.1.2 MACHINE LEVEL

Front to back: Within 5 mm (0.2") of level
Right to left: Within 5 mm (0.2") of level
SM
2-1
Installation Requirements
M118/M119