Truma 12V Fan Operation; Trumavent Teb With Automatic Speed Control 12V; Technical Data; Warm Air Distribution - Bailey Motorhomes Owner's Manual

Table of Contents

Advertisement

▲ Any alteration to the appliance (including exhaust duct and cowl) or the use of spare parts
and accessories which are important to the function of the heater and which are not original
Truma parts, as well as the non-observance of the installation and operating instructions,
will lead to the cancelling of the guarantee and exclusion of liability claims.
4.2.7

Technical Data

Power supply: ............................ 230v or 50Hz
Power consumption at power setting
................................................... 500 W: 2.2 A
................................................. 1000 W: 4.5 A
................................................. 2000 W: 8.5 A
4.3

TRUMA 12V FAN OPERATION

Fan operating instructions for warm air distribution and ventilation
4.3.1

Trumavent TEB with automatic speed control 12V

a = Manual control (e.g. for ventilation)
b = Off (or automatic operation/heating with heaters
Trumatic S 3002 K and S 5002 K)
c = Automatic operation (heating)
The output steadily adjusts to the respective heat
emission of the heater.
The maximum output can be limited at the control
knob, as required. The regulating between this
value and slow running is carried out automatically.
4.3.2
Technical Data
Power supply: .............................................12v
Power consumption: ...................... 0.3 to 1.0A
Air flow rate: .................. Up to 180.000 litres/h
4.3.3

Warm air distribution

The warm air system is designed individually for
each type of vehicle on a modular basis.
The quantity of air can be individually adjusted at
the air flap (Fig. 1:d) for warm air distribution. In
centre position 50% of the warm air is distributed
to each outlet.
Use the fan duct with a diameter of 72mm if the fan
ducts are of different lengths or on sides with a
Caravan Equipment
Weight: .......................................... approx 6kg
Adjust desired output at the control knob.
(with fan duct UR dia. 65mm)
Air flow rate: .................. Up to 205.000 litres/h
(with fan duct VR dia. 72mm)
Fig. 1
4