Structure (Technical) And New Functions - Electrolux GS 23 CH Service Manual

Electrolux dishwasher service manual
Hide thumbs Also See for GS 23 CH:
Table of Contents

Advertisement

5.4

Structure (technical) and new functions

2-key and 5-key Électronic
-
Électronic derived from series GS 23
-
All keys/switches to operate from the front
-
Snapped-on case
-
Single-board solution in SMD technology
-
Fibre optic between LED display and top of
case, snapped into the case from the front
-
Mechanical ram, incorporated in the case
cover, for transmission of input commands
-
Key caps slipped on new standard rubber
keypad
-
High-resistance signal inputs
-
Network inputs secured by VDR
-
All consumers Triac controlled
-
Pump capacity limited to 120VA by fixed
phase angle (half-load and/or AAA)
-
Temperature range from 0 to 60 °C
-
Humidity range from 35 to 85 rel%
Sensor Field Function
With the 8-sensor electronic, a second electronic system glued on to the glass back is assigned with the
function of the mechanical keys. Each sensor field generates a constant minute electrical field extremely
limited in space. If you approach your finger (or an object), this field is decreased in size. Such a
decrease is recognized by the sensor electronic and evaluated. Connection from sensor electronic to the
existing electronic is by means of a 10-pole low-tension wire within the panel.
The sensor electronic has a very simple structure and is insensitive against interference from outside ; in
case of faults, however, it must be exchanged along with the panel since it is glued on it.
In the following, for clear overview, we refer to « Keys » only, even when referring to sensors with the
highest comfort level.
Functions Half-load and Normal + Eco (AAA), as well as the existing pretests, have been taken over
from the existing series GS 23 without any changes.
Spares Operation 07.02 A. B.
8-sensor Électronic
-
Derived from 8-key and 7-key electronic of
series GS 23
-
Main switch to operate in the panel from
above
-
Snap-on case
-
Two-board solution in conventional
technology (wired elements)
-
LED direct through case surface
-
Sensor fields with ground-in finger guide in
the glass
-
High-resistance signal inputs
-
Network inputs secured by VDR
-
All consumers Triac controlled
-
Pump capacity limited to 120VA by fixed
phase angle (half-load and AAA)
-
Temperature range from 0 to 60 °C
-
Humidity range from 35 to 85 rel%