7-1-4. Stationary Heads Cleaning

n
Take care not to damage the surfaces of the stationary heads when cleaning.
Tools
. Cleaning cloth : 3-184-527-01
. Cleaning fluid : 9-919-573-01
Procedures
1. Clean the tape running surfaces of the FE, CTL and CUE/TC heads in the vertical direction using a
cleaning cloth moistened with cleaning fluid.
n
If the magnetic powder attached to the head gap portions of the FE, CTL and CUE/TC heads, an error
may occur when the recording or playback. Remove the magnetic powder completely.
2. After cleaning, be sure to wipe the tape running surfaces of the FE, CTL and CUE/TC heads using a dry
cleaning cloth.
CTL head
FE head
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P1
7-1. Cleaning
CUE/TC head
7-5