Setup Menu; Engineer Mode (Setup Menu) - Sony DIGITAL BETACAM DVW-707 Maintenance Manual

Digital betacam camcorder
Hide thumbs Also See for DIGITAL BETACAM DVW-707:
Table of Contents

Advertisement

This section describes details of the engineer mode of the setup menu that is displayed on the viewfinder.
It also describes the VTR (DIAG) menu that is displayed inside the display panel.

3-1. Engineer Mode (Setup Menu)

When you enter the engineer mode of the setup menu, the engineer-oriented menu appears. Using the
engineer-oriented menu, selection of user mode, various setting up and camera system adjustment can be
executed.
Data structure of the setup menu is described as shown below.
Setup values of the setup menu = Fixed data (absolute value) + Service mode setup value (relative value)
+ Engineer mode setup value (relative value) + User mode setup value (relative value)
Setup values of the setup menu
(adjustment value)
. When the MENU/ON/OFF switch is set to ON after turning on the main power, the camcorder enters
the user mode. When you enter the user mode, the page that is selected by the MENU SELECT page of
the engineer mode, and the items that are registered in the camera-man menu registration mode are
displayed in a maximum of five pages. (Refer to the operation manual for details of the user mode and
of the camera-man menu registration mode.)
. When an item is adjusted in the engineer mode, value of this item in the user mode is reset to 0.
. When a setup data is written in a setup card, the setup value in the user mode and the setup value is the
engineer mode are stored separately.
. Refer to the Maintenance Manual, Part 2, Volume 1, Section 2 for details of the service mode.
. When a remote control RM-B150/P9 is selected and the camcorder is operated externally from the
remote control, there are some items that cannot be changed of their setup or some items to which setup
data is not reflected correctly. Refer to Section "3-1-2 Setup Menu List" for more details.
How to Enter the Engineer Mode
1. Turn off the main power.
2. While pressing the rotary encoder, turn ON the POWER switch.
n
If you cannot enter the engineer mode, check the switch setting of the DCP-17 board for the follow-
ing.
S4-1 → OFF
→ OFF
S1
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P1
Section 3

Setup Menu

User mode data (relative value)
Engineer mode data (relative value)
Service mode data (relative value)
Fixed data (absolute value)
Stored in setup card
Default data when shipped
from factory