FujiFilm FinePix F601 Zoom Service Manual page 48

U/e/eg-model
Hide thumbs Also See for FinePix F601 Zoom:
Table of Contents

Advertisement

5. Inspection
<Step 10>
Item
Mode
Delete mode
Delete
check
<Step 11>
Item
Mode
Battery low
Auto Pho-
check
tography
LCD ON
<Step 12>
Item
Mode
Current con-
Auto Pho-
sumption
tography
check
LCD ON
<Step 13>
Item
Mode
Leakage cur-
Power OFF
rent check
<Step 14>
Item
Mode
Settings at
Auto Pho-
shipment
tography
Settings at
packaging
upgrade
48
Preparations for adjustment
and measurement
(1) Select Format from menu
and press OK button.
(2) Press OK button again.
Preparations for adjustment
and measurement
(1) Connect NP-60 battery jig.
(2) Set to end voltage.
Preparations for adjustment
and measurement
(1) Connect power supply
cable jig.
(2) Set voltage.
(3) Set mode dial to Camera
mode, and switch camera
power ON.
(4) Check current consump-
tion in viewfinder.
Preparations for adjustment
and measurement
(1) Switch power OFF.
Preparations for adjustment
and measurement
(1) Run Full Reset from Set-
tings menu to return to
defaults.
(2) Defaults are as follows.
Photography image dis-
play:
OFF
Auto power save:
2MIN
USB setting: Card reader
Beep:
LOW
LCD monitor: ON
Quality:
NORMAL
Date:
Not set
(3) Inspection battery/inspec-
tion SSFDC not in camera.
(4) No contamination on LCD/
EVF.
(5) Clean exterior of camera.
(1) No damage or contamina-
tion on exterior of camera
in STEP14 (5).
(2) Upgrade packaging in
accordance with parts list
details.
FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
Adjustment and measurement
method
(1) "Delete All Frames OK?" dis-
played.
(2) Playback screen disappears.
Adjustment and measurement
method
(1) See Battery Adjustment for
connections.
(2) Set voltage to 3.13±0.01V.
Lens retracts and camera
power is switched OFF.
Adjustment and measurement
method
(1) See DC jack adjustment for
connections.
(4) Maximum 550[mA].
Adjustment and measurement
method
(1) Leakage current maximum of
1mA.
Adjustment and measurement
method
(1) The camera may be set to the
mode set at shipment from the
factory with the following pro-
cedure.
1. Connect the camera to the
computer with the USB cable.
2. Open the battery cover.
3. Switch power supply ON (AC
adapter may also be used).
4. Switch power ON while
pressing the shutter button.
5. Switch the power supply OFF
with the camera POWER
button.
Measuring
Measurement
instrument
point
LCD monitor
Recorded
smart media
Measuring
Measurement
instrument
point
Battery jig
Stabilized
power sup-
ply
Measuring
Measurement
instrument
point
Power sup-
ply cable jig
Ammeter
Measuring
Measurement
instrument
point
Power sup-
LCD monitor
ply cable jig
Ammeter
Measuring
Measurement
instrument
point

Advertisement

Table of Contents
loading

Table of Contents