FinePix F601 Zoom (U/E/EG) SERVICE MANUAL
5.

Inspection

5-1. Measuring Instruments and Jigs Used for Inspection
Measuring instrument
TV monitor
Power supply
Pattern box
Waveform monitor
Digital voltmeter
Luminance meter
Color thermometer
Ammeter
NP60 battery jig
Power cable jig
Grey chart
LB140 filter
High-resolution chart
5-2. Connection of Measuring Instruments for Inspection
* As the FinePix F601 has no video output, the FinePix4800Z is used to illustrate connection of the measuring
instruments.
Any other camera with a video output function may also be used provided that it is not malfunctioning.
(AC-5VH, stabilized power supply)
5-3. Inspection and Settings at Shipment
<Step 1>
Item
Mode
Visual check
------
Remarks
NTSC TV monitor, minimum resolution 600 lines
AC adapter (eg AC-5VH), stabilized power supply
PTB450 or equivalent
LEADER: 5870 or equivalent
For general use
LS-110 (Minolta) or equivalent
Color Meter IIIF (Minolta) or equivalent
For general use (able to measure up to 1mA)
Common with adjustment jig: ZJ00496-100
Common with adjustment jig: ZJ00213-100
Common with adjustment jig: ZJ00254-100
Common with adjustment jig: ZJ00006-100
Common with FinePixS1Pro, FinePix4700Z: ZJ00398-100
VIDEO OUT
FinePix4800Z
Amme-
ter
Power supply
Preparations for adjustment
and measurement
Visual check of camera.
Vector
scope
Waveform
monitor
Adjustment and measurement
method
• No significant dents in body.
• Click sound of all switches, and
operation of sliders, normal.
• No significant foreign matter, or
cloudiness, in viewfinder.
• Flash mechanism opens and
closes smoothly.
5. Inspection
TV monitor
Measuring
Measurement
instrument
point
------
------
45