C8
DRAIN / REFILL / TOP-UP : 4 HP 20 GEARBOX
Engine : XFW
Checks (continued)
With the engine running at the temperature 55° ± 1°C, open the top-up plug (3).
Wait for the temperature to reach 60° ± 1°C.
1st possibility :
- Oil flows out, the level is correct.
- Refit the top-up plug (3), tighten to 2,5 ± 0,2 m.daN.
2nd possibility :
- Oil does not flow out.
- Refit the top-up plug (3).
- Add 0,5 litres of oil. (Refer to the chapter on refilling).
Repeat the procedure of checking the oil level.
Refit the metallic part of the vent plug (2), using an 18mm dia. punch and a
mallet.
Clip the plastic part of the vent plug (2).