Shutdown Diagnostics - Viper 5301 Installation Manual

Responder le model 5301 remote start keyless entry
Hide thumbs Also See for 5301:
Table of Contents

Advertisement

Note: An optional push button can be hard wired to the (-) activation input of the
system to activate turbo timer manually.
When the vehicle is running follow the procedures listed above, but instead
of pressing the remote, press the push button the appropriate number of times
to activate the remote start (factory setting is for 1 pulse). The remote emits the
remote start confirmation tone, after which you can turn off the ignition and exit
the vehicle. The car remains running for the pre-programmed amount of time.

Shutdown diagnostics

To perform shutdown diagnostics:
1.
With the ignition OFF, press and hold the Valet/Program switch.
2.
Turn the ignition ON and then back OFF while holding the Valet/Pro-
gram switch.
3.
Release the Valet/Program switch.
4.
Press and release the Valet/Program switch. The LED flashes on the con-
trol center to report the last shutdown for one minute or until the ignition
is turned on, as shown in the following table:
LED Flashes
1
2
3
4
5
6
7
8
9
10
11
*
Timer mode error: Ignition is on or shutdown input is active when activating
timer mode.
Turbo mode error: Turbo mode is programmed off, engine is not on or
shutdown input is active.
Manual mode error: MTS not enabled.
© 2008 Directed Electronics. All rights reserved.
Shutdown Mode
Runtime expired
Over-rev shutdown
Low or no RPM
Transmitter shutdown (or optional push button)
(+) Brake shutdown
(-) Hood shutdown
Timer mode/Turbo mode/Manual mode error *
Neutral safety shutdown
Low battery (voltage mode)
-------------------------------------------------------
Wait-to-start input timed out