3. SIGNALS AND WIRING
3.3.3 CNP1, CNP2, CNP3 wiring method
Use the supplied servo amplifier power supply connectors for wiring of CNP1, CNP2 and CNP3.
(1) MR-J3-100B or less
(a) Servo amplifier power supply connectors
(Note)
Servo amplifier power supply connectors
<Applicable cable example>
Cable finish OD: to
3.8mm
Note. These connectors are of insert type. As the crimping type, the following connectors (molex) are recommended.
For CNP1: 51241-0600 (connector), 56125-0118 (terminal)
For CNP2: 51240-0500 (connector), 56125-0118 (terminal)
For CNP3: 51241-0300 (connector), 56125-0118 (terminal)
Crimping tool: CNP57349-5300
<Connector applicable cable example>
Cable finish OD: to
(b) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is.
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take care to avoid
a short caused by the loose wires of the core and the adjacent pole. Do not solder the core as
it may cause a contact fault. Alternatively, a bar terminal may be used to put the wires
together.
Cable size
[mm
1.25
1.5
2
POINT
Refer to Table 11.1 in Section 11.8 for the wire sizes used for wiring.
MR-J3-500B or more does not have these connectors.
Connector for CNP1
54928-0610 (molex)
Connector for CNP2
54927-0510 (molex)
Connector for CNP3
54928-0310 (molex)
3.8mm
2
]
AWG
For 1 cable
BT1.25-9-1
16
TUB-1.25
16
AI1.5-8BK
BT2-9-1
14
TUB-2
Servo amplifier
CNP1
CNP2
CNP3
Sheath
Core
8 to 9mm
Bar terminal type
For 2 cables
AI-TWIN2
1.5-8BK
AI-TWIN2
1.5-12BK
3 - 10
Crimping tool
NH1
NICHIFU
YHT-2210
JST
CRIMPFOX-UD6
Phoenix Contact
NH1
NICHIFU
YHT-2210
JST
Maker