11. OPTIONS AND AUXILIARY EQUIPMENT

11.8 Recommended wires

(1) Wires for power supply wiring
The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
Power supply
2) Control power supply lead
6) Brake unit lead or
Return converter
Brake unit or
Return converter
Regenerative brake option
Note. There is no L
3
The following table lists wire sizes. The wires used assume that they are 600V vinyl wires and the wiring
distance is 30m(98.4ft) max. If the wiring distance is over 30m(98.4ft), choose the wire size in consideration
of voltage drop.
To comply with the UL/C-UL (CSA) Standard, use UL-recognized copper wires rated at 60°C (140°F) or
more for wiring.
Servo amplifier
1) L
1
MR-J3-10B (1)
MR-J3-20B (1)
MR-J3-40B (1)
2 (AWG14)
MR-J3-60B
MR-J3-70B
MR-J3-100B
MR-J3-200B
3.5 (AWG12)
MR-J3-350B
5.5 (AWG10)
MR-J3-500B
5.5(AWG10): b(note)
MR-J3-700B
8(AWG8): c(note)
Note. For crimping terminals and applicable tools, refer to Table 11.2.
POINT
Refer to Section 11.1.5 for SSCNET cable.
1) Main circuit power supply lead
4) Regenerative brake option lead
for 1-phase 100 to 120VAC power supply.
Table 11.1 Recommended wires
L
L
2) L
2
3
11
1.25 (AWG16)
3) Motor power supply lead
Servo amplifier
L
U
1
L
V
2
L
(Note)
W
3
L
11
L
21
N
C
P
C
P
2
Wires [mm
]
L
3) U V W
21
1.25 (AWG16)
2 (AWG14)
3.5 (AWG12)
5.5 (AWG10)
5.5(AWG10): b(note)
8(AWG8): c(note)
11 - 36
Servo motor
4) Electromagnetic
brake lead
B1
B2
Encoder cable
4) P C
2(AWG14)
1.25 (AWG16)
3.5(AWG12): b
U
V
Motor
W
Electro-
magnetic
brake
Encoder
5) B1 B2