Mitsubishi Electric MR-J3-B Instruction Manual page 174

Melservo-j3 series servo amplifier
Hide thumbs Also See for MR-J3-B:
Table of Contents

Advertisement

11. OPTIONS AND AUXILIARY EQUIPMENT
(c) When fabricating the encoder cable
When fabricating the cable, prepare the following parts and tool, and fabricate it according to the wiring
diagram in (b). Refer to Section 11.8 for the specifications of the used cable.
(3) MR-J3JCBL03M-A1-L MR-J3JCLB03M-A2-L
The servo amplifier and servo motor cannot be connected with these cables only. The servo motor side
encoder cable (MR-EKCBL
Parts/Tool
Connector set
MR-ECNM
For CN2 connector
Connector housing: 54593-1011
Cover A: 54594-1015
Cover B: 54595-1005
Shell cover: 58935-1000
Shell body: 58934-1000
Cable clamp: 58937-0000
Screw: 58203-0010
(Molex)
M-L/H) is required.
Cable Model
Length
MR-J3JCBL03M-A1-L
MR-J3JCBL03M-A2-L
Cable
Protective
Structure
0.3m
IP20
11 - 11
Description
Junction connector
Housing: 1-172161-9
Connector pin: 170359-1
(Tyco Electronics or equivalent)
Cable clamp: MTI-0002
(Toa Electric Industries)
Flex Life
Application
For HF-MP HF-KP servo motor
Load side lead
Use in combination with MR-EKCBL
M-L/H.
Standard
For HF-MP HF-KP servo motor
Opposite-to-load side lead
Use in combination with MR-EKCBL
M-L/H.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents