Host Parameters - Motorola Symbol DS3408 Product Reference Manual

Hide thumbs Also See for Symbol DS3408:
Table of Contents

Advertisement

7 - 4
Symbol DS3408 Product Reference Guide
RS-232 Host Parameters
Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, Wincor-Nixdorf
Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults listed in
Terminal Specific RS-232
Table 7-2
Parameter
Transmit Code ID
No
Data Transmission
Data as is
Format
Suffix
CR/LF
(7013)
Baud Rate
9600
Parity
None
Hardware
None
Handshaking
Software Handshaking
None
Serial Response
2 Sec.
Time-out
Stop Bit Select
One
ASCII Format
8-Bit
Beep On <BEL>
Disable
RTS Line State
Low
Prefix
None
*In the Nixdorf Mode B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled.
**If you select Nixdorf Mode B without connecting the digital scanner to the proper host, it may appear
unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the
digital scanner.
Standard
ICL
(Default)
Yes
Yes
Data/Suffix
Data/Suffix
CR (1013)
CR (1013)
9600
9600
Even
None
RTS/CTS
None
Option 3
None
None
9.9 Sec.
2 Sec.
One
One
8-Bit
8-Bit
Disable
Disable
High
Low
None
None
Wincor-N
Fujitsu
ixdorf
Mode A
OPOS/JPOS
Yes
Yes
Data/Suffix
Data/Suffix
CR (1013)
CR (1013)
9600
9600
Odd
Odd
RTS/CTS
RTS/CTS
Option 3
Option 3
None
None
9.9 Sec.
9.9 Sec.
One
One
8-Bit
8-Bit
Disable
Disable
Low
Low = No
data to send
None
None
Table 7-2
Wincor-
Nixdorf
Olivetti
Mode B/
Yes
Prefix/Data/
Suffix
ETX (1002)
9600
Even
None
Ack/Nak
9.9 Sec.
One
7-Bit
Disable
Low
STX (1003)
Omron
Yes
Data/Suffix
CR (1013)
9600
None
None
None
9.9 Sec.
One
8-Bit
Disable
High
None

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Symbol ds3408-sfSymbol ds3408-hd

Table of Contents