TurboChef i3 Service Manual page 86

Rapid cook oven
Hide thumbs Also See for i3:
Table of Contents

Advertisement

A-10 APPENDIX - REPLACING OVEN COMPONENTS
Removing Right Side Cover Required (Figure A-9)
CAUTION: Before removing/installing any component, make sure it is disconnected from the
wire harness (where applicable).
CAUTION: Be careful to not tear the insulation when servicing components. Always reset the
insulation properly before reinstalling the side panel.
Hardware listed is required for installing component to oven.
To remove the right side cover:
1. Remove the screws securing the panel to the oven frame.
2. Remove the right side cover.
Figure A-9: Removing Right Side Cover Required
Figure
Item Description
Reference #
1
Catalytic Converter
N/A
Cover, Right Side
2
Heater Assembly
3
Helper Spring, Interlock Switch*
4
Interlock Switch - Monitor*
5
Interlock Switch - Secondary*
6
Mounting Bracket, Interlock Switch*
N/A
RTD, Cook Cavity
7
Shield, Heater Insulation (x2)
8
Thermostat, High-Limit
* NOTE: For more interlock switch detail, see Figure A-10, page A-11.
1
8
3
4
5
6
Item Part Number Hardware Description
i3-9066
None
i3-9302
Screw, #8, Serr PPHD, Truss, Black Oxide 101691 (qty 5)
i3-9380
Screw, Sh Mtl #8 x 1/2, Serrated PHTRH
i5-9397
None
102012
Screw, #4-40 x 1", PPH, Sems
102012
Screw, #4-40 x 1", PPH, Sems
i5-9272
Screw, #10-32 x 3/4 lg, PPH Sems, Int Th 102937 (qty 2)
HHC-6517-2
Screw, Sh Mtl #8 x 1/2, Serrated PHTRH
i5-9216
None
102075
Screw, M4 x 6, PPH SQ CO Sems, Zinc
7
2
Hardware Part Number(s)
None
101688 (qty 10)
None
102903 (qty 2)
102903 (qty 2)
101688 (qty 2)
None
101672 (qty 2)