Side Panel Removal

The procedures to remove both the left and right
side panels are identical.
1.
Disconnect power to the range.
2.
Remove the range from its installation.
3.
Raise and support the cooktop or remove the
cooktop. (See
Cooktop Assembly
4.
Remove the hidden screw near the front leveling
leg.
5.
Remove the four screws from the rear of the
side panel.
6.
.)
Note: The front of the panel is held to the range
frame by 3 plastic grommets that engage 3 keyhole
slots placed along the inside front fl ange of the
panel.
7.
– 41 –
Remove the three top screws and maintop strike
from the top of the side panel.
Maintop Strike
Grasp the front and rear portion of the side
panel. Lift the side panel up and pull towards
you then disengage the three rubber grommets.
A
Grommet
Engaged (A)
B
Grommet
Disengaged (B)
Plastic Grommet
Plastic Grommet