Remove Motor
08-0050
Cover
RLY1 Sequence (10 sec.)
RLY1 will be on at power up
Power down unit-
and stay on for a 10 second
Press Power
switch, then Power
duration. During the
back up. Check for
sequence, RLY2 will come on
RLY1 Sequence.
after 9 seconds and then
RLY1 will go out after 10
seconds. RLY2 will remain on.
Sequence OK- RLY1
YES
initiates, but no RAIL &
unit goes into SI2
NO
If RLY1 does not
come on during
sequence- go to
next step
Remove and re-install
Console Panel and
Encoder Harness
plugs on M/C board
and Console Panel
Check Calibration
settings- CL25
Check Calibration
setting CL25- AL1 or
AL1
AL2
AL2
Re-Calibrate unit
SI 2 Code:
Over-Voltage Protection
Unit is ON, No Belt Movement
Check M/C
Part Number
Replace F1 fuse
Replace Console
Wire Harness
13-0016
Plug in unit,
check for RAIL
08-0051
LED (Remove
motor cover)
OFF
Check R64- Is
resistor burned-
up?
NO
Check F1
(AC side)
GOOD
Check F2
(DC side)
GOOD
Replace M/C
Board
Check Drive
Motor wire
ON
connections on
M/C (M+,M-)
Check F2 and
replace if blown
Replace M/C
YES
Board
Replace Fuse
BAD
and Re-test unit
Replace Fuse
BAD
and Re-test unit