To remove the drain pump:
Note: Water will remain in hoses even when the tub
appears empty. Use care to avoid water spills.
1. Disconnect power to the machine.
2. Remove the 4 Phillips-head screws (2 on each
side) that hold the back cover in place. Remove
the back cover.
3. Remove the thin plastic cover over the drain
pump by pulling down on the ends to clear the
tabs.
4. Remove the drain hoses from the pump:
Note: The drain hoses are diffi cult to remove due to
a sealing compound used at the factory.
a. Squeeze each clamp and slide it back.
b. Carefully break each hose loose by inserting
a small fl at-blade screwdriver under the
hose to break the seal.
c. Remove the hoses.
Clamps
5. Remove the 2 Phillips-head screws that hold the
drain pump mounting plate to the washer fl oor.
6. Disconnect the drain pump wires.
7. Remove the 2 Phillips-head screws that hold the
drain pump to the mounting plate. Remove the
drain pump.
Caution: Care must to taken when reinstalling and
sealing the drain hoses to the outer tub to ensure
there is no water leakage.
When installing, apply a thin coat of sealing
compound (part no. WH60X15) to the inner surface
of the drain hoses.

Thermistor/ATC Control (Auto Temp)

The control uses a water temperature sensor
(thermistor) to regulate the wash water
temperature.
The thermistor has a negative temperature
coeffi cient (as temperature increases, resistance
decreases).
The thermistor is located in the bottom of the
outer tub under the wash basket.
Thermistor
– 32 –
Disconnect
Bottom View
(Continued Next Page)