Inverter; Membrane Keypanel - GE Profile Harmony WPGT9360 Technical Service Manual

Harmony washer
Table of Contents

Advertisement

Membrane Keypanel

The membrane keypanel is attached to the
backsplash and is only available as a complete
assembly.
When ordering a replacement backsplash, the
part must be ordered as left or right, depending on
installation.
The membrane keypanel is connected to the control
board by a ribbon cable.
Membrane Keypanel Test
To test the membrane keypanel, press the
appropriate pad and check for continuity (0 Ω)
between the following pins:
Pad
Pins
Power
1 and 3
My Cycles
1 and 4
Back
2 and 3
Help
2 and 4
Home
1 and 7
Start/Stop
1 and 5
7
5
4
3
2
1
Note: The number (1) molded on the membrane
connector is not a pin reference number.

Inverter

The inverter board is enclosed in a protective
box that is mounted on the top cover under the
backsplash. The inverter is held in place by 2 Phillips
head screws.
The heating element control board is mounted to
the inverter box and is held in place by 2 Phillips
head screws.
Inverter
To access the inverter board, lift the inverter box up.
Press the tabs on the side and gently pry it open.
MEMBRANE
RIBBON
– 24 –
Heating Element Control Board