Automatic Temperature Control (Atc) - GE WPRB9250 Technical Service Manual

Profile stainless steel washer
Hide thumbs Also See for WPRB9250:
Table of Contents

Advertisement

To remove the lid lock:
1. Place the control panel in the service position (see
Control Panel).
2. Disconnect the lid lock harness connector.
3. Remove the front panel (see Front Panel).
4. Remove 2 screws securing the lid lock to the top
panel.
5. Remove 2 screws securing the top panel to the
cabinet and lift the front of the top panel.
6. Remove the lid lock.
Water Valve
The water valve is a 120 VAC, double solenoid type,
which is accessed by placing the control panel in the
service position.
The water valve wiring is equipped with snubbers, on
each water valve connector, to reduce EMI. A shorted
snubber may cause a failure to occur on the electronic
control board (see Electronic Control Board).

Automatic Temperature Control (ATC)

The automatic temperature control feature is used to
provide optimum wash water temperature. The ATC
uses a water temperature sensor (thermistor) with a
negative temperature coefficient (as temperature rises,
resistance lowers), located in the top of the hose and
water inlet to detect incoming water temperature. The
electronic control board uses the difference between
the voltage sent to the water temperature sensor and
voltage returning from the water temperature sensor to
determine the temperature of the incoming water, and
to make (ATC) decisions.
The ATC should maintain the water temperature in the
tub within the ranges specified in the Water
Temperatures chart by opening or closing the hot and
cold water valves.
To prevent sudden water temperature changes on
consumer's hands, the ATC does not function when
the lid is open during warm or cold fill.
Note:
The ATC will flush the water inlets with hot water for
the first 6 seconds of a warm wash cycle.
During cold water fill, the hot water valve will open if
the water inlet temperature is too cold.
Water Valve
Water Valve
Snubber
Snubber
Thermistor
Thermistor
Hose and
Hose and
Water Inlet
Water Inlet
Lid Switch
A
T
T
e
m
p
e
a r
u t
e r
S
e
t t
n i
g
H
t o
W
r a
m
C
o
d l
– 24 –
2 Lock Clips
Lock Connector
Lid Switch
Lock
C
T
e
m
p
e
a r
u t
e r
C
h
a
t r
W
a
s
h
R
n i
T
e
m
p
e
a r
u t
e r
s
T
e
m
p
e
1
1
5
+
- /
8
F °
N
8
0
+
- /
7
F °
7
0
+
6
0
+
- /
7
F °
a T
p
W
s
e
a r
u t
e r
s
A /
- /
7
F °
t a
r e

Hide quick links: