To remove the clutch shifter assembly:
1. Remove the rotor. (See
2. Remove the three Phillips-head screws from the
clutch coupler plate.
3. Remove the clutch coupler assembly.
4. Disconnect the wiring connector from the clutch
motor.
5. Remove the two 10-mm hex-head screws that
hold the clutch motor in place. Remove the
clutch motor.
Disconnect
)
Motor Assembly.

Bearing Housing Assembly

To remove the bearing housing Assembly:
1. Remove the
Motor Assembly
.
Assembly
2. Remove the Phillips-head screw that holds the
ground wire to the bearing housing. Remove
the 10-mm hex-head screws on the bearing
housing assembly.
4. Remove the bearing housing assembly.
Note: When reassembling, be sure to put the motor
and Hall sensor wires back in the wiring guard away
from the motor.
– 41 –
and
Clutch Shifter
Ground