Central Pneumatic 95218 Assembly And Operation Instructions Manual page 6

Nailer/stapler oil free - 18 gauge
Table of Contents

Advertisement

TESTING THE SINGLE SEQUENTIAL SAFETY TRIP MECHANISM
WARNING: Even though the Nailer should be empty during this procedure, ALWAYS point
the Nailer at a piece of scrap wood when testing. Always wear ANSI-approved
safety goggles.
1.
Make sure the tool is disconnected from its air supply.
2.
Completely empty the Moveable Magazine (61) of Brads or Staples.
DRIVER GUIDE (62)
3.
The Nailer/Stapler should not fire if the Driver Guide (62) is not depressed against
the workpiece.
4.
Make sure the Trigger (32) and Driver Guide (62) move freely, without sticking.
5.
Connect the air supply to the tool at the Air Inlet Plug (78). Set the regulator at
the recommended 90 to 125 operating PSI. Do not exceed the maximum 125
PSI.
6.
Test the tool by depressing the Driver Guide (62) against the workpiece without
pulling the Trigger (32). The tool must not cycle (fire). If it cycles (fires), stop
immediately and have it repaired by a qualified service technician.
7.
Hold the tool away or off the workpiece. The Driver Guide (62) of the tool should
return to its original position. Squeeze the Trigger (32). The tool should not cycle
(fire). If the tool cycles (fires), stop immediately and have it repaired by a qualified
service technician.
8.
Depress the Driver Guide (62) against the workpiece and squeeze the Trigger (32).
The tool must cycle (fire) only once. Release the Trigger and squeeze it again.
The tool must cycle (fire) only once. With the Trigger held, carefully lift the Nailer
and press it against the workpiece again. The tool must not cycle (fire). If it fails
to perform in the manner explained in bold, have it repaired by a qualified service
technician.
For technical questions, please call 1-800-444-3353
SKU 95218
TRIGGER
(32)
AIR INLET PLUG
(78)
FIXED LEVER (53)
MOVEABLE MAGAZINE
(61)
PAGE 6