BDV Series Gas Fireplace SIGNAtuRE cOMMAND SyStEM OpERAtION INStRuctIONS
FEAtuRES
Command Center
•
Easy Access Function Operation and System Configura-
tion
•
Operation Confirmation/Fault Diagnostic Indications (LED/
Buzzer)
•
ON/OFF/HI/Low Operation
control Board
•
Electronic Ignition
•
Pilot Lockout safety feature
•
Electric Power Regeneration from Thermopile to save bat-
tery
•
6-hour Automatic Shut Down Option
•
Convenient NG/LP Gas Type Conversion
•
Standing Pilot/Intermittent pilot Conversion
•
Previous settings Restoration Ability
•
Uninterrupted Operation During Power Outage (Automatic
Battery Backup)
•
ON/OFF RF Remote Receiver
•
Optional Transmitter Learn Capability
AC Interface Board (Optional)
•
Easy Snap-on Design
•
Embedded Compact 120 VAC Adapter with Auto Battery
Back up Feature
•
Remote Controlled Blower, Lighting, and Auxiliary AC Outputs
Transmitter (Optional)
Three Flame Height Settings
Low battery Indication for Transmitter
Child Proof Lock-out
LCD Backlight
Security Codes
Thermostatic Control Mode
Three Brightness Settings for Lights
Three Speed Control for Blower
On/Off Auxiliary
Programmable Timer to turn blower on and off
BAttERy INStALLAtION
The Command Center uses four (4) "AA" batteries.
to Install Batteries:
1. Press down the battery door tabs and pull out to remove battery door.
2. Install the batteries as indicated on Command Center.
3. Close battery door by snapping in place.
4. When the four (4) batteries are installed the system is ready for use.
5. The batteries should be replaced when the LED indicates low battery.
44
RF Receiver
ON/OFF
NG/LP
Conversion
control
Board
Command
center
Master Switch
Figure 58 - Signature Command System
Components
RFSC
RTSC
X
X
X
X
X
X
X
X
X
X
X
X
X
--
X
--
X
--
X
--
To Thermopile
To Sensor
To Command
Center
To Stepper Motor
To Valve
Battery Door
ON
LED
OFF
FP1917
Signature components
8/08
RMSC
X
X
X
X
X
--
--
--
--
--
To Sparker
54D0700