BDV Series Gas Fireplace
cLEARANcES tO cOMBuStIBLES
Follow these instructions carefully to ensure safe installation. Failure to
follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other combustible
material other than wood flooring. If installed on carpet or vinyl flooring, the
appliance shall be installed on a metal, wood or noncombustible material
panel extending full width and depth of the appliance.
71" Minimum
Minimum 4"
From Both
Side Walls
Figure 5 - Clearances
MANtEL cLEARANcES
NOtE: The combustible area above the facing must not protrude more than 3/4" from the
facing. If it does, it is considered a mantel and must meet the mantel requirements listed in
this manual.
10
Maximum
11" Minimum
FP2092
FP2092
mantel clearance
12"
Depth
FP2093
Figure 5a - Mantel Clearances
cLEARANcES
1"
1.5"
1.5"
2.5"
3"
4"
FP2093
mantel leg clearance
11/08
Wall
Combustible
Material Area
3.5"
3.5"
4.5"
45°
54D0700