Lighting Millivolt Pilot For The First Time; Lighting Millivolt Pilot - Monessen Hearth BDV300 Installation And Operating Instructions Manual

Bdv series irect vent gas fireplace
Table of Contents

Advertisement

OPERATING INSTRUCTIONS (MIllIVOlT)
LIGhtING pILOt FOR thE FIRSt tIME
AppROVED LEAK tEStING MEthOD
You may check for gas leaks with the following methods only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer
Never check for gas leak with open flame!
Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections
• Pilot
• Each joint or connection
The control has an interlock device that does not allow the lighting of the fireplace up
to the moment the safety device of the flame has not interrupted the gas flow. After
that period of time (when the magnet is closed), it is possible to start the lighting
operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools
during this operation. Damaged knobs may result in serious injury.
1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. Depress
piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to
burn.
If the pilot does not stay lit, repeat steps 1 and 2.
54D0700
• Field made joints / gas shutoff valve
• Factory made joints
• All joints on valve and control body
LIGhtING pILOt
BDV Series Gas Fireplace
If using a soap and water
solution to test for leaks,
DO NOt spray solution onto
control body.
NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
P I L
O T
Figure 45 - Pilot Position
Continued on next page
FP1935
control knob pilot
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bdv400Bdv500Bdv600

Table of Contents