9. CIRCUIT CONFIGURATION AND CONTROL SPECIFICATIONS

9-1. Outdoor Controls

9-1-1. Print Circuit Board
<Viewed from parts of P.C board>
RAV-SP1104AT-E, RAV-SP1404AT-E
RAV-SP1104ATZ-E, RAV-SP1404ATZ-E
RAV-SP1104ATZG-E, RAV-SP1404ATZG-E
<MCC-1571>
Case thermostat connector
CN609 (Blue)
Power supply circuit protective fuse
F100 250V, 3.15A, Plastic case)
4-way valve connector
CN701 (White)
Compressor ON output connector
CN704 (Blue)
Heater output connector
CN610 (Gray)
Outside input connector
CN610 (Yellow)
Specific operation switch
SW801
SW804
Display select switch
SW800
SW803
Temp. sensor connector
TL CN604 (White)
TD CN603 (White)
TO CN602 (Yellow)
TE CN601 (White)
TS CN600 (White)
Power-ON, error display LED
D800 to 804 (Yellow)
D805 (Green)
PMV connector
CN710 (White)
Initial setting switch
SW802
Indoor/Outdoor communication signal LED
D503 (Green, Outdoor → Indoor)
D502 (Orange, Indoor → Outdoor)
Fan motor output
Fan motor output
(Lower side)
(Upper side)
CN300 (White)
CN400 (White)
Inter-unit
cable connector
CN04 (White)
4-way valve protective fuse
F700 (250V, 3.15A, Plastic case)
www.ilmalämpöpumput.com
Compressor output terminal
CN202
CN201
CN200
Connector
Connector
for reactor
for reactor
Inter-unit cable
protective fuse
F03 (250V, 25A)
– 76 –
Lead wire
Lead wire
for grounding
for grounding
P09 (Black)
P09 (Black)
Connector
Connector
for reactor
for reactor
Power supply
protective fuse
F01 (250V, 25A)
Lead wire for connection of power supply
P01 (Red)
P02 (White)
Electrolytic
condenser