Toshiba RAV-SM564UT-E Service Manual page 112

Air-conditioner split type
Hide thumbs Also See for RAV-SM564UT-E:
Table of Contents

Advertisement

Toshiba SDI / DI tuotteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy.
Check
Outdoor
code
LED display
[H04]
<Display 1> <Display 2>
l
l
¡
l
¡
¡
[L10]
<Display 1> <Display 2>
l
¡
¡
l
¡
¡
(Item without special mention Indicates part of outdoor unit.)
[Case thermostat operation]
l
l
l
Are CN609 connection
and case thermostat normal?
¥
l
YES
¡
Is cooling/heating operation
available when short-circuiting
case thermostat?
YES
Is there no gas leak?
Is it not refrigerant shortage?
YES
Is valve fully opened?
YES
Is PMV normal?
YES
[Unset model type]: Only when service P .C. board is used
l
¥
l
Cut jumper line according
to the explanation sheet packaged
¥
with the service P.C. board.
l
¡
www.ilmalämpöpumput.com
– 112 –
<In case of SP110, SP140>
Check and troubleshooting
NO
Case thermostat error → Replace
NO
Check outdoor P.C. board.
NO
Repair defectives position.
NO
NO
Correct defective position.
Replace defective part.
Check crushed or broken pipe.
Defect → Correct and Replace
Correct connector.
Defect → Replace
Recharge refrigerant.
Open valve fully.