Toshiba RAV-SM564UT-E Service Manual page 169

Air-conditioner split type
Hide thumbs Also See for RAV-SM564UT-E:
Table of Contents

Advertisement

Toshiba SDI / DI tuotteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy.
2) Error display
The error which is generating at present and the latest error (Latest error information including present)
can be confirmed by lighting LED D800 toD804 on the outdoor control P .C. board.
a) When all DIP switch SW803 are OFF, the status of error which is generating at present is displayed.
b) <1> only of DIP switch SW803 is turned on, the error which generated before
(Latest error information including present) is displayed.a)
c) If there is an error, any of LED D800 to D804 goes on. (Display 1)
d) When pushing the pushdown button switch SW800 for approx. 1 second, the display is exchanged.
(Display 2)
e) When pushing SW800 again or after 2 minutes, the status returns to that of Display
Present error
Latest error
SW803
SW803
Display 1)
Display 2)
(Initial display)
(SW800 operation)
lllll
lllll
¡
ll
l
¥¥
¥¥¥
lll
ll
¡¡
¡¡
ll
l
¥
¥¥¥¥
¥¥¥¥¥¡
llll
¥
l
¥
ll
l
¡
¡¡
¥¥
ll
l
¥
l
l
l
¡¡
¡¡
¥
¥¥¥¥¥¡
¥¥
l
¥
¥¥¥
¥¥¥¥
l
¡¡¡
¡¡
¥¥
ll
l
¥¥
l
¥
l
¥
∗ As the error code displayed on the wired remote controller may differ according to type of indoor model, multiple
codes are described.
(Legend)
l
D800 (Yellow)
l
D801 (Yellow)
¥
D802 (Yellow)
l
D803 (Yellow)
l
D804 (Yellow)
¡
D805 (Green)
¡
Normal
ll
¥
¡
Discharge temp. sensor (TD) error
ll
¡
Heat exchanger temp. sensor (TE) error
ll
¡
Heat exchanger temp. sensor (TL) error
l
¥
¡
Outside temp. sensor (TO) error
l
¥¥
¡
Suction temp. sensor (TS) error
l
¥¥
¡
Heat sink temp. sensor (TH) error
l
¡
Heat exchanger sensor (TE, TS) miswiring
EEPROM error
¡
Compressor break down
lll
¡
Compressor lock
lll
¡
Current detection circuit error
ll
¥
¡
Case thermostat operation
l
l
¥
¡
Model unset
¥¥¥¡
Communication error between MCU
Other error (Compressor disorder, etc.)
lll
¡
Discharge temp. error
ll
¥
¡
Power supply error
ll
¡
Heat sink overheat error
l
¡
Gas leak detection
ll
¥¡
4-way valve reverse error
l
¥
¥¡
High pressure protective operation
l
¥¡
Fan system error
l
¥¥¡
Driving element short-circuit
¥¥¥¡
Position detection circuit erro
www.ilmalämpöpumput.com
Error contents
– 169 –
<In case of SP110, SP140>

.
l
¡
¥
: Go off,
: Go on,
Wired remote controller
Error code
F04
F06
F06, F07
F08
F06, F12
F13, L29
F06, F15
F31, L29
H01
H02
H03
H04, P04
L10, L29
L29
Error is not determined.
P03
P04, P05
P07, L29
P15, L29
P19, L29
P04, P20
P22
P26
P29
: Flash

Hide quick links:

Advertisement

Table of Contents
loading