Toshiba RAV-SM304SDT-E Owner's Manual
Hide thumbs Also See for RAV-SM304SDT-E:

Advertisement

AIR CONDITIONER (SPLIT TYPE)
Owner's Manual
Indoor Unit
Model name:
Slim Duct Type
RAV-SM304SDT-E
RAV-SM404SDT-E
RAV-SM454SDT-E
RAV-SM564SDT-E
For commercial use
For commercial use
English

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAV-SM304SDT-E

  • Page 1: Προφυλάξεις Ασφαλείας

    AIR CONDITIONER (SPLIT TYPE) Owner’s Manual Indoor Unit For commercial use For commercial use Model name: Slim Duct Type RAV-SM304SDT-E RAV-SM404SDT-E RAV-SM454SDT-E RAV-SM564SDT-E English...
  • Page 2: Table Of Contents

    • The qualified installer is a person who installs, maintains, relocates and removes the air conditioners made by Toshiba Carrier Corporation. He or she has been trained to install, maintain, relocate and remove the air conditioners made by Toshiba Carrier Corporation or, alternatively, he or she has been instructed in such...
  • Page 3: Precautions For Safety

    Precautions for safety  Warning indications on the air conditioner unit The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual. Warning indication Description WARNING WARNING WARNING General ELECTRICAL SHOCK HAZARD •...
  • Page 4: Правила Техники Безопасности

    – 3 –  Information on the transportation, handling and storage of the • Consult the shop where you purchased the air conditioner if air conditioning (cooling and heating) is not performed properly as a refrigerant leakage may be the cause. Confirm the repair details with a qualified service person(*1) when the repair carton includes additional charging of the refrigerant.
  • Page 5 • L’installateur qualifié est une personne qui installe, entretient, déplace et enlève les climatiseurs fabriqués AVERTISSEMENT par Toshiba Carrier Corporation. Il ou elle a été formé pour installer, entretenir, déplacer et enlever les climatiseurs fabriqués par Toshiba Carrier Corporation ou, alternativement, il ou elle a reçu des consignes Moving parts.
  • Page 6: Parts Name

    Parts name Wired remote controller This remote controller can control the operation of up to 8 indoor units.  Indoor unit  Display section In the display illustration below all the icons are shown. When the unit is in Air intake Earth screw operation, only relevant icons will be displayed.
  • Page 7: Operation Section

    – 29 –  Operation section Push each button to select a desired operation. • The details of the operation needs to be set up once, afterward, the air conditioner can be used by pushing button only. Fan speed display Central control display The selected fan speed mode is displayed.
  • Page 8: Correct Usage

    Correct usage In case of automatic operation (Auto Changeover) • Because of some settings change, it will automatically select either cooling, heating, or fan only operation depending on the indoor temperature. When you use the air conditioner for the first time or when you change the SET DATA value, follow the procedure below. From •...
  • Page 9: Timer Operation

    – 31 – Timer operation Power saving mode • A type of timer operation can be selected from the following three types. (Setting of up to 168 hours is enabled.) The power saving mode saves energy by limiting the maximum current which will effect heating or cooling capacity that the unit can generate.
  • Page 10: Maintenance

    Maintenance ◆ Check periodically • If the unit is used for a long time, parts may deteriorate and cause malfunction or bad drainage of dehumidified water depending on the heat, humidity, or dust. WARNING • In addition to the usual maintenance, it is recommended that you have the unit checked and maintained by the dealer where you purchased it.
  • Page 11: Troubleshooting

    – 33 – Troubleshooting  Confirmation and check  Confirmation of error log When an error occurred in the air conditioner, an error code When an error occurred on the air conditioner, the error log Check the points described below before requesting repair. and indoor UNIT No.
  • Page 12: Operations And Performance

    Operations and performance Installation ▼ Check before running ▼ Protective device ◆ Do not install the air conditioner in the following places • Check whether the earth wire is cut or disconnected. • Stops operation when the air-conditioner is overloaded. •...
  • Page 13: Specifications

    Model Weight (Kg) Cooling Heating RAV-SM304SDT-E Authorized Nick Ball RAV-SM404SDT-E Representative / Toshiba EMEA Engineering Director RAV-SM454SDT-E TCF holder: Toshiba Carrier UK Ltd. RAV-SM564SDT-E Porsham Close, Belliver Industrial Estate, * Under 70 dBA PLYMOUTH, Devon, PL6 7DB. United Kingdom Hereby declares that the machinery described below:...
  • Page 14 MEMO ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 15 – 37 – MEMO ..........................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 16 MEMO ....................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 17 (Name of the manufacturer) TOSHIBA CARRIER CORPORATION 23-17 Takanawa, 3-Chome, Minatoku, Tokyo (Address, city, country) 108-8580 Japan (Name of the Importer/Distributor in EU) Toshiba Carrier UK Ltd. Porsham Close, Belliver Industrial Estate, PLYMOUTH, (Address, city, country) Devon, PL6 7DB. United Kingdom EH99940201-1...

This manual is also suitable for:

Rav-sm404sdt-eRav-sm564sdt-eRav-sm454sdt-e

Table of Contents