Cr Motor Removal - Epson Stylus Photo895 Service Manual

Color inkjet printer
Table of Contents

Advertisement

EPSON Stylus PHOTO 895/785EPX/915/825

4.2.5 CR motor removal

1.
Remove the Housing from the printer. (Refer to Section 4.2.1 "Housing
Removal")
2.
Using tweezers or a small screwdriver, slide the CR Lock Lever to front and
release the CR Lock Lever from the CR unit.
3.
Loosen the CR Timing Belt by pushing the Driven Pulley Holder to right using a
screwdriver, and remove the Timing Belt carefully from the pinion gear on the CR
motor. Refer to Figure 4-17. "Removing the Timing Belt".
Disassembly and Assembly
CR Timing belt
Figure 4-17. Removing the Timing Belt