Cr Motor Removal - Epson Stylus 1500 Service Manual

Hide thumbs Also See for Stylus 1500:
Table of Contents

Advertisement

CR Motor Removal

1.
Remove the upper housing. (See page 3-7.)
2.
Disconnect the cable from the CR motor.
3.
Remove the timing belt spring to loosen belt tension. Then remove the timing belt from the CR
motor pulley.
4.
Tip the CR motor unit slightly clockwise. Then remove the motor from the base frame
(procedures 1 to 3 below).
If you remove the CR motor, perform the Uni-D and Bi-D adjustments. (See Chapter 4.)
Do not damage the surface of ink supply tube.
When assembling the CR motor, do not catch the cable for the DE sensor between the
base frame and middle frame unit.
Never touch the white PF gears. Handling them will cause damage or contamination that
will affect print quality.
DISASSEMBLY/ASSEMBLY POINT
In using adhesive on the CR motor fan to attach the CR motor shaft, place the shaft within
1 mm of the back of the fan and set the sink side of fan toward the outside. (See Chapter 6.)
CR Moto r
Figure 3-9. Applying Adhesive to the CR Motor Fan
EPSON Stylus 1500 Service Manual
CR Motor Unit
Base Frame
Timing Belt
Figure 3-8. Removing the CR Motor
REQUIRED ADJUSTMENTS
CAUTION
Disassembly and Assembly
CR Motor Cable
Timing Belt Spring
Less than 1 mm
Ad he sive Point
Sink side
CR Motor Fan
3-13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents