3.2.6.6 CR Motor Assembly Removal

Step 1) Remove the printer mechanism. (See Section 3.2.6.1.)
Step 2) Remove 1 extension spring (3275) on the top edge of the printer mechanism to
loosen the timing belt.
T e n s i o n S p r i n g ( 3 2 7 5 )
C R B e l t L e v e r
B e l t S u b P u l l e y S e t
C R
Step 3) Remove 1 screw (CBS, 3X6) securing the grounding plate for the external cooling
fan FFC, and remove the grounding plate for the FFC.
Step 4) Remove 4 screws (CS, 3X16) securing the CR motor assembly to the CR frame
and 1 screw (CBS, 3X6) securing the CR motor grounding plate to the CR frame.
Then remove the CR motor assembly.
C B S S c r e w ( 3 X 6 )
G r o u n d i n g P l a t e f o r F F C
Perform "Bi-D adjustment" after replacing the CR Assembly or removing/replacing the
timing belt.
3-16
Figure 3-17. CR Motor Assembly Removal
Figure 3-18. CR Motor Assembly Removal
WORK POINT
C B S S c r e w ( 3 X 6 )
C R F r a m e
P u l l e y
C R T i m i n g B e l t
C R T i m i n g B e l t
C R F r a m e
C R M o t o r D a m p e r
C R M o t o r D a m p e r
C R M o t o r A s s e m b l y
G r o u n d i n g P l a t e f o r C R M o t o r
C B S S c r e w ( 3 X 6 )
C S S c r e w s ( 3 X 6 )
C S S c r e w s ( 3 X 6 )
C R M o t o r A s s e m b l y
Rev. A