Service Manual
10.1.3 Preparations forreassembly
•
Remove seat unit (see chapter9.1.5).
•
Remove clamp and seat tube (see chapter 9.1.6)
•
Carefully pull the chassis panelling upwards off the Velcro connectors.
10.1.4 Reassembly information for "removing the battery pack"
•
Separate the battery cable connecting plug (1).
•
Remove the battery pack from the chassis.
10.1.5 Reassembly information for "replacing the main fuse"
The fuse holder (2) is inserted in the battery cable bridge.
It is fitted with a turn-lock fastener.
10.1.6 Reassembly sequence for "replacing the battery"
•
Loosen the battery cable in the following sequence:
1. Remove the cable bridge negative terminal with main fuse.
2. Remove the cable bridge positive terminal with main fuse.
3. Loosen the battery cable negative terminal.
4. Loosen the battery cable positive terminal.
CAUTION:
•
Risk of short circuit.Take care with tools.Do not bridge battery terminals
10.1.7 Reassembly information for "replacing the controller"
•
Disconnect all connecting plugs on the controller
Plug allocation:
1. Power feed battery cable
2. Drive unit
3. Operating unit
•
Replace controller.
Phillips screws (a) / nuts (size 8 mm)
As at: 15.04.02
Invacare
Page 27
®
Electra
Battery plug
Main fuse
Removing the battery
cable
Plug allocation: