8.3 Fault and diagnosis codes

If there is an electrical fault, this is displayed by the fact that the power pilot
light (11; status display) in the operating unit blinks.
This displays an error code which allows an approximate fault diagnosis.
The diode (11) then flashes in a particular blink sequence.
The electronics system is able to correct some errors automatically.
Switch the Scooter off, wait five seconds, and then switch it on again.
The test checks whether the error can be automatically rectified by the electronics, and if necessary
deactivates the blinking status display at the operating unit.
If the error cannot be rectified, limit the source of error using the "Status display error codes" table (see
chapter: 8.3.1 page: 13).
8.3.1

Status display error codes

Localise the error using the brink codes as follows:
turn the operating unit off and on again
check which blink code is showing by counting
wait for the blink code pause (approx. 2-3 seconds)
re-count the code.
Error code:
Error:
Batteries are discharged
1 x blink
Battery voltage too low
2 x blink
Battery voltage too high
3 x blink
Cause:
Current delay exceeded
4 x blink
Cause:
Motor short-circuit
5 x blink
Motors disengaged
Braking coil defective
6 x blink
Drive lever is not in neutral position
when switching on
Speed controller defective
7 x blink
Motor voltage error
8 x blink
Internal error
9 x blink
As at: 15.04.02
the batteries can be charged during downhill runs and during braking by the
motor return current.
maximum battery current supplier can be exceeded due to motor overload
(for example running against an immovable obstacle)
Page 13
Invacare
Status display
Immediate measure:
Charge battery
charge batteries
Remove battery charger from charging
socket
Turn the Scooter off and then on again
Switch the Scooter off and then on again
after a few minutes
Check wiring harness for short-circuit
Check motor
Press disengaging lever in
Replace drive unit
Ensure that the drive lever is in the central
position; turn the operating unit off and on
again
Replace speed controller
Replace drive unit
Ascertain error message using programming
device and evaluate
®