Appendix; Charging Of Fully Discharged Batteries; Connecting The Programming Device; Preparation - Invacare Electra Service Manual

Scooter
Hide thumbs Also See for Electra:
Table of Contents

Advertisement

Service Manual

12 Appendix

12.1 Charging of fully discharged batteries

If a voltage of less than 9.5 V is measured at a battery, the battery is fully discharged. Also observe the
information on the charging of batteries contained
in the vehicle Operating Manual
in the charger Operating Manual
on the charger
CAUTION:Risk of accidents!
Batteries are not allowed to lie on their sides or stand on edge while being charged.
For charging a fully discharged battery, proceed as follows:
Remove the batteries from the vehicle.
Pre-charge each battery individually while simultaneously measuring the charging voltage.
Pre-charge battery up to 10 V by means of an unregulated charger.
Then stop charging procedure.
CAUTION:Explosion hazard!
Do not fully charge batteries using an unregulated charger.
Put batteries back into the vehicle.
Fully charge battery using the Invacare charger via the Scooter charging socket .
The charging procedure should last for at least 48 hours.

12.2 Connecting the programming device

12.2.1 Preparation

Secure the Scooter against rolling away by blocking the front wheel with wedges.
Raise the rear of the Scooter until the drive wheels can turn freely and support by blocking up the anti-
tipper wheel.
You will now be able to check drive commands because the drive wheels can turn freely.
CAUTION:Danger because Scooter can roll away!
Secure the Scooter against rolling away by blocking the front wheel with wedges before
raising.
As at: 15.04.02
Invacare
Page 35
®