High Altitude Adjustment

Installations burning natural gas and located at altitudes
from 2000 - 4500 ft. (610 M - 1370 M), require compensa-
tion for the thinner air (less volume of air per cubic foot).
Higher altitudes affect the atmospheric pressure and
heat value of gaseous fuels. The lower oxygen content in
the air and the lower gas viscosity require the use of a
different orifice to achieve efficient, clean combustion at
the burner tube.
For high altitude installations consult the local gas
distributor or the authority having jurisdiction for proper
rating methods. If the installer must convert the unit to
adjust for varying altitudes, use Jøtul High Altitude Kit,
#155885-LP or # 155895 NG.
DO NO
DO NO
DO NOT DER
T DER
T DERA A A A A T T T T T E E E E E T T T T T H H H H H E BU
T DER
DO NO
DO NO
T DER
In In In In In the U
the U
the U
the U.S:
the U
.S: THE DERATING KIT MUST BE INSTALLED BY AN
.S:
.S: .S:
AUTHORIZED SERVICE TECHNICIAN IN ACCORDANCE WITH
THE MANUFACTURER'S INSTRUCTIONS AND ALL CODES
AND REQUIREMENTS OF THE AUTHORITY HAVING JURIS-
DICTION. THE INFORMATION STICKER MUST BE COM-
PLETED BY THE INSTALLER AND APPLIED TO THE APPLI-
ANCE AT THE TIME OF THE CONVERSION. THE QUALIFIED
SERVICE AGENCY PERFORMING THIS WORK ASSUMES
RESPONSIBILITY FOR THIS DERATING.
In Canada:
In Canada:
In Canada:
In Canada: This unit has been tested for installation at
In Canada:
high altitudes in accordance with Canadian test standard
CAN/CGA-2.17. THE DERATING SHALL BE CARRIED OUT IN
ACCORDANCE WITH THE REQUIREMENTS OF THE PROVIN-
CIAL AUTHORITIES HAVING JURISDICTION AND IN ACCOR-
DANCE WITH THE REQUIREMENTS OF THE CAN1-B-149.1
AND .2 INSTALLATION CODE.
AVERTISEMENT:
CET EQUIPEMENT DE CONVERSION SERA INSTALLE PAR UNE
AGENCE QUALKFIEE DE SERVICE CONFORMENMENT AUX
INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET
CODES APPLECABLES DE L'AUTORISES AVOIR LA JURIDICTION.
SI L'INFORMAITON DANS CETTE INSTRUCTION N'EST PAS
SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION
DE PROTOXYDE DE CARBONE PEUT RESULTER LE DOMMAGES
CAUSER DE PROPRIETE, PERTE OU BLESSURE PERSONNELLE DE
VIE. L'AGENCE QUALIFIEE' DE SERVICE EST ESPONSABLE DE
L'INSTALLATION PROPRE DE CET EQUIPEMENT.
L'INSTALLATION N'EST PAS PROPRE ET COMPLETE JUSQU'A
L'OPERATION DE L'APPAREIL CONVERTI EST CHEQUE SUIVANT
LES CRITERES ETABLIS DANS LES INSTRUCTIONS DE
PROPRIETAIRE PROVISIONNEES AVEC L'EQUIPEMENT.
E BUR R R R R N N N N N ER F
E BU
E BU
ER FOR PR
ER F
ER F
OR PR
OR PR
OR PROP
OP
OPAN
OP
ANE. E. E. E. E.
AN
AN
E BU
ER F
OR PR
OP
AN
Air Shutter
Wingnut
FRONT
LEG
Figure 51. Locate and remove the Air Shutter wingnut from
under the right side of the stove.
Air Shutter
Burner Plate
Burner Plate
Burner Plate
Burner Plate
Burner Plate
Figure 52. Remove the Air Shutter and Burner as a unit.
Derating Procedure
1. Follow Steps 1-10 of the Fuel Conversion procedure
outlined on pages 11 and 12.
2. Replace the original orifice with the appropriate orifice in
the kit: 3.10 mm NG or #51 LP.
3. Fill out the high altitude conversion label from the kit
and attach to the rating plate or gas valve.
4. Reassemble the firebox components.
5. It may be necessary to adjust the air shutter on the
burner tube. See AIR SHUTTER/FLAME APPEARANCE on
page 16 for more details.
Open
Close
BACK
LEG
23