Jøtul GF 400 BV Sebago Installation And Operation Instructions Manual page 9

Direct vent gas stove
Table of Contents

Advertisement

• When 6" diameter decorative pipe is installed to
cover the venting any Listed Flexible Gas liner must
be connected directly to the stove's draft hood.
• Use of single wall connector pipe as a vent is prohib-
ited for use with the GF400 Sebago B-Vent stove.
• A firestop is required at every floor.
• Any venting that is exposed above the first floor,
regardless of attic space or living space, must be
enclosed. Always maintain the required clearance
from all sides of the vertical vent system according
to manufacture.
• Installation of any components not manufactured or
approved by Jøtul or failure to meet all clearance
requirements will void all warranties and could result in
property damage, bodily injury, or serious fire.
• Never modify any venting component, or use any
damaged venting product.
• THE GAS APPLIANCE AND VENT SYSTEM MUST BE
VENTED DIRECTLY TO THE OUTSIDE OF THE BUILD-
ING, AND NEVER ATTACHED TO A CHIMNEY SERVING
A SOLID FUEL OR GAS BURNING APPLIANCES.
• BE SURE TO MAINTAIN THE PROPER CLEARANCES TO
COMBUSTIBLES AS DEFINED IN THIS MANUAL AND IN
THE INSTRUCTIONS PROVIDED WITH EACH VENTING
COMPONENT.
• When installing at an altitude above 2000' the
minimum vertical rise becomes 12' from the draft
hood.
A chimney system located outside the building
envelope may be subject to downdrafting
and/or flow reversal. Atmospherically-vented
appliances, such as B-Vents, may not be compat-
ible with these chimney systems.
All atmospherically-vented appliances (B-Vents)
are affected by atmospheric conditions and house
pressurization. For example, a B-Vent appliance
vented to an outside chimney system in a base-
ment will likely be subject to negative pressure.
This type of installation is not recommended.
NOTE:
Venting through a Masonry or
Prefabricated Manufactured
Chimney
Top sealing
achor plate
Type B vent or
Listed Flexible Gas
Liner.
Use of Type B vent
liner within
outside chimneys
is recommended
to help keep the
gases warm and
stabilize draft.
Max. Height 35 ft.
Min. Height 7 ft.
Always
maintain
the proper
clearance to
mantel and
Maximum
offset is 4 ft.
Recommended
damper sealing
plate to seal flue
chamber to prevent
heat loss
WARNING: FAILURE TO POSITION THE PARTS IN
ACCORDANCE WITH THIS DIAGRAM OR FAILURE TO USE
ONLY PARTS SPECIFICALLY APPROVED WITH THIS
APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR
PERSONAL INJURY.
Figure 6. Venting through a masonry chimney.
Storm collar
termination
required
cap required
trim
Listed
9