Control Panel; Top Cover; Washer Components - GE WCVH4800K Technical Service Manual

24-in. ha washer
Table of Contents

Advertisement

Top Cover

WARNING: Sharp edges may be exposed when
servicing washer. Use caution to avoid injury and
wear Kevlar gloves or equivalent protection.
Note: Combined Phillips-head and metric hex-head
screws can be utilized throughout this appliance.
Either a Phillips screwdriver or metric wrench can be
used to extract or install these screws.
Removal of the top cover provides access to the
control panel, dispenser, water valves, water level
sensor, and line fi lter. Two Phillips-head screws are
located at the rear of the top cover.
Top View
After removal of the screws, the cover can then be
slid rearward 1 inch, then lifted to disengage it from
the cabinet.

Washer Components

Control Panel

The control panel is held in place with 4 Phillips-
head screws and 4 tabs. Two tabs engage the front
brace and 2 tabs engage the cabinet front.
To remove the control panel:
1.
Remove the top panel. (See
2.
Pull the dispenser out to the stop position.
3.
Press down on the lock tab, then pull the
dispenser out from the control panel.
4. Remove the 2 Phillips-head screws from the
control panel dispenser recess.
– 25 –
.)
Top Cover
Lock Tab
(Continued Next Page)