Clearance To Combustibles Without Rear Shield; Alcove Installation; Stove Installation - Napoleon 1600C-1 Installation And Operating Instructions Manual

Table of Contents

Advertisement

2.1

CLEARANCE TO COMBUSTIBLES WITHOUT REAR SHIELD

Do not install into any area having less than 7 feet (ceiling of enclosure to appliance bottom, excluding
For reduced clearances, installation must comply with NFPA 211 or CAN/CSA-B365. For clearances when
installed with blower kit EP63, see "CLEARANCE TO COMBUSTIBLES WITH REAR SHIELD INSTALLATION"
section.

2.1.1 ALCOVE INSTALLATION

Model 1600C-1 may be installed into an alcove having
a depth of not more than 4 feet and a height of at least
7 feet, when using a listed double wall connector that
is rated for a minimum 12" clearance to combustible
material.
Walls shall not extend from the front of the appliance
when installed in the alcove confi guration.

2.1.2 STOVE INSTALLATION

If the appliance is to be installed on a combustible fl oor, it must be placed on a approved non-combustible
hearth pad, that extends 8" (200mm) beyond the appliance sides and back, and 18" (455mm) to the front.
TYPE
WITHOUT REAR
A
B
C
CLEARANCES TO CHIMNEY
CONNECTOR
SINGLE WALL
25"
CLEARANCES TO UNIT
SINGLE WALL
WITH REAR SHIELD
SHIELD
16"
24"*
15"
DOUBLE WALL
18"
When using a
double wall con-
nector listed for a
minimum clear-
ance of 12" or
less.
WARNING
!
hearth height).
16"
22"
16"
4 FT
WITHOUT REAR
SHIELD
16"
16"
15"
8"
B
8"
8"
18"
ILLUSTRATED WITH .75" HEART PAD
DOUBLE WALL
WITH REAR SHIELD
16"
16"
18"
12"
11"
11"
C
A
W415-0721 / 05.06.09
9
84"
C

Advertisement