PRODuct FeAtuReS
PRODuct SPecIFIcAtIONS
•
This appliance has been certified for use with
either natural or propane gas. Refer to the appro-
priate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance is approved for bedroom or bedsit-
ting room installations.
•
The appliance must be installed in accordance
with local codes if any. If none exist use the cur-
rent installation code. ANSI Z3.1/NFPA 54 in
the USA, CSA B149 in Canada.
•
This appliance is mobile home approved.
•
The appliance must be properly connected to a
venting system.
•
The appliance is not approved for closet or
recessed installations.
hIGh eLeVAtIONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370 m)
above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installation must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installation at elevations above
4,500 feet (1,370 m).
GAS PReSSuReS
Inlet Minimum
Inlet Maximum
Manifold Pressure
83D4009
Figure 1 -
VLIDV Series Fireplace Insert Controls
Natural
Propane (LP)
4.5" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10.0" w.c.
FP2677
GAS SPecIFIcAtIONS & ORIFIce SIZe
VLI31 controls
Model
Fuel
VLI31DVNTSC
Nat.
VLI31DVPTSC
LP
VLI31 Fireplace Insert
FP677
Max.Input Min. Input
Orifice
Btu/h
Btu/h
3,000
,500
3,000
5,500
Gas Shut
Off
Command
Center
Size
#35
#51