Vermont Castings VLI31DVN Installation And Operating Instructions Manual page 20

Vlidv series direct vent gas fireplace insert
Table of Contents

Advertisement

VLI31 Fireplace Insert
Before you begin - This unit is supplied with seven (7) ceramic fiber logs. Do not handle these logs with
your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling
the logs, wash your hands gently with soap and water to remove any traces of fibers.
the positioning of the logs is critical to the safe and clean operation of this heater.
Sooting and other problems may result if the logs are not properly and firmly posi-
tioned in the appliance. Never add additional logs or embellishments such as pine
cones or vermiculite to the heater. Only use the logs supplied with the unit.
Failure to position the parts in accordance with diagrams below or to use only parts
specifically approved for this heater may result in property damage or personal
injury.
PLAce ROcK WOOL (eMBeR MAte-
RIAL) IN FIReBOx
Break up rock wool (ember material) into dime-sized
pieces. Place evenly over burner, both in front and
behind the fettle. Make sure to cover all of the ports
but do not cover the slotted ports in rear. Apply rock
wool in light fluffy pieces to better enable gas to
permeate the rock wool. Figure 16
Do not use the entire
bag of rock wool to
cover burner area.
LOG PLAceMeNt
1. Place Log #1 in front of the light box located in the
rear of the unit. This is held in place with an "L"
shaped bracket. Figure 17
. Hold Log # with the flat edge to the right and the
keys on the log pointing up. Place the log on the
pins provided inside the right brick and behind the
fettle. Figure 17
0
Figure 16 -
Rock Wool Placement
LG828
rockwool area
Log #1
Figure 17
LG828
VLI31 log 1 & 2
LOG PLAceMeNt
LG88
Log #
LG88
83D4009