6.4 Mono PA + Monitor

In this application the left power amp output channel is used for the MONITOR signal. The right power amp output chan-
nel is used for a mono PA, the MASTER B output is used as signal source. The MASTER B signal has to be configured as
follows:
• MASTER B control at position „5"
• PRE/POST switch set to POST (pressed)
• STEREO/MONO switch set to MONO (pressed)
Illustration 6-4: Mono PA + Monitor