Parameter
Function
Enable
You need to draw a circle here so that system can detect the alarm signal.
There are two options: normal open and normal close. NO becomes activated in
Type
low voltage, NC becomes activated in high voltage.
Alarm record function becomes activated in the specified periods.
There are six periods in one day. Please draw a circle to enable corresponding
period.
Period
Select date. If you do not select, current setup applies to today only. You can
select all week column to apply to the whole week.
Click OK button, system goes back to alarm setup interface, please click save
button to exit.
Anti-dither
Not effective in current DVR version.
Enable alarm activation function. You need to select alarm output port so that
Normal Out
system can activate corresponding alarm device when alarm occurs.
Alarm
System can delay the alarm output for specified time after alarm ended. The value
Latch
ranges from 10 seconds to 300 seconds.
System auto activates current channel to record once alarm occurs (working with
Record
alarm activation function). Please note current device shall be in auto record mode
Channel
(Chapter 4.4 Schedule).
Record
System can delay the record for specified time after alarm ended. The value
Latch
ranges from 10s to 300s.
Please draw a circle to enable email function. System can send out email to alert
Email
you when alarm occurs and ends.
Display video in local monitor window by tour. if there're record channels selected,
Tour
only the record channels will be displayed in the tour.
Here you can set PTZ movement when alarm occurs. Such as go to preset x
PTZ
when there is an alarm.
activation
The PTZ configuration events include preset, auto-tour, and pattern.
It is a shortcut menu button. You can copy current channel setup to one or more
Copy
(all) channels.
You can click save button after you complete setup for one channel, or you can
Save
complete the whole setups and then click save button.
Refresh
Click this button to get device latest configuration information.
Detect
Analysis the video, the system enables motion detection alarm when it detects the
motion signal reached the specified sensitivity.
The detection interface is shown as in
Figure
6-39.