Optional Equipment
8. Remove the four screws holding the control cover in place (see picture below). Pull the control cover
forward slightly and disconnect the flame height knob (do not remove the knob). This allows the
control cover to move upwards, away from the concealment cover.
9. Pull the control cover forward, taking care to not damage any wiring (see picture below). This will
allow access to the gas control valve.
10. Replace the regulator following the instructions included with the regulator kit. Remove and discard
the screws (see "a" below) holding the stock regulator in place (see "b" below). Remove the stock
regulator and gasket (see "c" below). Place the LP regulator in place, making sure the pre-fitted
gasket (see"c" below) is in place – make sure it is correctly oriented. Secure using the screws
included with the motor – tighten to 25 Lb-inches. Leak test this area after installation to verify
proper installation. There is a label on the base of the regulator knob indicating regulator type (NG
or LP). Place the included label on the valve body where it can be easily seen to insure proper
identification ("d").
11. Replace the firebox components.
12. Restore the appliance to the correct configuration. Make the gas line connection, bleed the gas line
(if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve.
© Travis Industries
(
for qualified installers only)
a
T-20 Torx or
Slotted Screwdriver
b
d
4140813
c
37
100-01296