Installation (for qualified installers only)
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture
and draperies.
Side
k
Wall
l
Mantel Clearances
The maximum mantel depth is 12" (305mm).
NOTE:
The combustible area above the facing must not protrude more than 3/4" (20mm) from
the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this
manual.
Modifying the Face Connector for Discovery, Rosario, and Artisan Faces
The Discovery, Rosario, and Artisan face require re-positioning of the face connector. See the
directions below for details.
© Travis Industries
n
m
x
Remove the face connector bracket
from the heater (on both sides).
4140813
Minimum
Clearances
k Sidewall to Insert
4-1/2"
115mm
4-1/2"
l Side Facing
(non-combustible)
115mm
m Top Facing*
35"
889mm
(non-combustible)
n Mantel*
35"
(combustible or
889mm
non-combustible)
x Hearth Extension
1-1/4"
(3-Piece Panel)
32mm
x Hearth Extension
0"
(1-Piece Panel)
0mm
Re-attach the face connector to the
heater using the forward mounting holes.
Face Connector
Bracket