Clearances; Mantel Clearances; Modifying The Face Connector For Discovery, Rosario, And Artisan Faces - Travis Industries 31 DVI GSB2 Owner's Manual

Direct vent fireplace insert
Table of Contents

Advertisement

Installation (for qualified installers only)

Clearances

Due to the high temperature of the heater, it should be located out of traffic and away from furniture
and draperies.
Side
k
Wall
l

Mantel Clearances

The maximum mantel depth is 12" (305mm).
NOTE:
The combustible area above the facing must not protrude more than 3/4" (20mm) from
the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this
manual.

Modifying the Face Connector for Discovery, Rosario, and Artisan Faces

The Discovery, Rosario, and Artisan face require re-positioning of the face connector. See the
directions below for details.
© Travis Industries
n
m
x
Remove the face connector bracket
from the heater (on both sides).
4140813
Minimum
Clearances
k Sidewall to Insert
4-1/2"
115mm
4-1/2"
l Side Facing
(non-combustible)
115mm
m Top Facing*
35"
889mm
(non-combustible)
n Mantel*
35"
(combustible or
889mm
non-combustible)
x Hearth Extension
1-1/4"
(3-Piece Panel)
32mm
x Hearth Extension
0"
(1-Piece Panel)
0mm
Re-attach the face connector to the
heater using the forward mounting holes.
Face Connector
Bracket
11
100-01296