MAINTENANCE
All maintenance must be carried out by a licensed quali ed service person
IT IS CRITICAL THAT THIS APPLIANCE IS EARTHED AND THAT THE ACTIVE AND NEUTRAL ARE NOT REVERSED
UNIT OPERATION
No gas to the burner
Unit sparks, main burner ignites a er 5 seconds
spark con nues even though main ame is present
Convec on fan operates but no
igni on a er approx 1 minute
er res
ng igni on module, unit s ll not
opera ng a er 1 minute
40
ACTION REQUIRED
The gas valve should open at the same me the igni on commences sparking. If
there is no gas to the burner, turn unit o . Connect manometer to inlet test point
on the gas valve and check sta c pressure. If O.K. turn unit on and check there is
no signi cant drop in the pressure. If O.K. connect manometer to outlet test point
of the gas valve, turn unit on and check outlet pressure is present whilst the spark is
being generated.
This can be caused by incorrect polarity.
Check that the wall socket to the appliance has correct polarity. If an extension lead
is
ed check polarity of the lead. Check the polarity of the supply lead to the
appliance. NOTE: The above checks must be carried out by a quali ed person
Igni on module is in lockout, reset module.
Then turn on again.
NOTE: On ini al light up this may occur a number of mes un l any residual air is
purged from the gas line through the burner system. It is essen al the required
wai ng me as stated in the manual is observed prior to a
Turn burner switch to "ON", fans will operate within 25 secs, listen for audible "click" rst from
igni on module, then from pressure switch.
If no "click' heard contact service agent
mp ng re igni on
Regency GF900C Gas Fireplace