Regency GF900C-NG Owners & Installation Manual page 16

Table of Contents

Advertisement

INSTALLATION
Description
Attic Insulation Shield 12"
Attic Insulation Shield -
Cold Climates
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Extended Vertical Termination Cap
Chimney Conversion Kit A (USA only)
Chimney Conversion Kit B (USA only)
Chimney Conversion Kit C (USA only)
Chimney Conversion Kit Masonry
(USA only)
Wall Firestop
Colinear Flex Connectors
FPI
946-506/P
Vent Guard (Optional) for AstroCap
510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
946-605
Starter Collar Increaser 4" x 6-5/8" to 5" x 8"
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
4" x 6-5/8" Venting
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
16
Selkirk
Simpson
®
Direct Temp™
Direct Vent Pro
46DVA-IS
N/A
N/A@ FPI
36"
N/A
N/A
Disc.
4DT-HKA
46DVA-KHA
4DT-HKB
(Changed Components)
Disc.
4DT-VKC
46DVA-VCH
N/A
46DVA-HC
N/A
46DVA-08A
4DT-SC
46DVA-F6
4DT-ST14
46DVA-FLA
4DT-ST36
46DVA-VSS
4DT-VS
N/A
4DT-VSP
46DVA-SNKL
N/A
N/A
N/A
N/A
N/A
N/A
N/A
46DVA-KCA
N/A
46DVA-KCB
N/A
46DVA-KCC
N/A
46DVA-KMC
N/A
46DVA-WFS
N/A
46DVA-ADF
N/A
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
American Metal
Metal-Fab™
Products®
Sure Seal
Amerivent Direct
4DAIS12
N/A
4DAIS12
N/A
4DHTK2
4DHTKA
4DHTK1
4DHTKB
4DHTK
4DHTK
N/A
N/A
N/A
N/A
4DSC
4DSC
4D12S
4DST14
4D36S
4DST36
N/A
4DVS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
946-205
Vinyl Siding Shield for Riser Vent Terminal
946-208/P
Vent Guard (Optional) for Riser Vent Terminal
946-523/P
AstroCap Horizontal Cap
946-206
Vinyl Siding Standoff for AstroCap
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Security
ICC Excel
Secure- Vent®
Direct
SV4RSA
N/A
N/A
TM-4AS
SV-SHK
N/A
SV-HK
N/A
SV-FK
N/A
N/A
TM-4VT
N/A
TM-4DHT
SV4FC
TM-SC
SV4STC14
TF-4FA
SV4STC36
TF-4FB
SV4VS
TM-VSS
SV4VS
N/A
N/A
TM-4ST14
N/A
TM-4ST36
N/A
TM-4DS
N/A
N/A
N/A
TM-4CA6
N/A
TM-4CA7
N/A
TM-4CA8
N/A
N/A
N/A
TM-4TR
N/A
N/A
Regency GF900C Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gf900c-lpgGf900c-ulpg

Table of Contents