HP ProLiant DL380 G6 User Manual page 84

Hide thumbs Also See for ProLiant DL380 G6:
Table of Contents

Advertisement

The external health LED is red or amber.
The internal health LED is red or amber.
NOTE:
For the location of server LEDs and information on their statuses, refer to the server
documentation.
Possible causes:
Improperly seated or faulty power supply
Loose or faulty power cord
Power source problem
Power on circuit problem
Improperly seated component or interlock problem
Faulty internal component
Item
See
"Server health LEDs (on page 80)" and "Component identification (on
1
page 7)"
"HP Insight Diagnostics (on page 72)" or in the HP ProLiant Servers
2
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 75)"
"Loose connections (on page 79)"
3
Server maintenance and service guide, located on the Documentation CD,
4
or the HP website (http://www.hp.com/products/servers/platforms)
"Integrated Management Log (on page 72)" or in the HP ProLiant Servers
5
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 75)"
"Power source problems" in the HP ProLiant Servers Troubleshooting Guide
6
located on the Documentation CD or see "Troubleshooting resources (on
page 75)"
7
"Power supply problems" in the HP ProLiant Servers Troubleshooting
Guide located on the Documentation CD or see "Troubleshooting
resources (on page 75)"
Server maintenance and service guide, located on the Documentation
CD, or the HP website
(http://www.hp.com/products/servers/platforms)
"System open circuits and short circuits" in the HP ProLiant Servers
8
Troubleshooting Guide located on the Documentation CD or see
"Troubleshooting resources (on page 75)"
Troubleshooting 84

Advertisement

Table of Contents
loading

Table of Contents