Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power
HP ProLiant 750 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Rated steady-state power
Maximum peak power
HP ProLiant 460 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
10 A at 100 VAC
4.9 A at 200 VAC
930 W at 100V AC input
1348 W at 200V AC input
3530 at 120V AC input
4600 at 200V to 240V AC input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
Value
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
8.9 A at 100 VAC
4.3 A at 200 VAC
857 W at 100V AC input
824 W at 200V AC input
2925 at 100V AC input
2812 at 200V AC input
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Value
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
5.5 A at 100 VAC
2.6 A at 200 VAC
526 W at 100V AC input
505 W at 200V AC input
1794 at 100V AC input
1725 at 200V AC input
Specifications 102